sending...
Warning:

We encountered error while submitting the form.

Ok

Products

Sandwich Panel Thermal Properties

Tempcon Panels

Tempcon sandwich panels are produced using rigid Polyisocyanurate (PIR) foam core with external and internal sheets in steel or aluminum of varying thickness, coatings and colors. Tempcon is a durable sandwich panel, particularly in industrial buildings and are suitable for roof and wall for all building applications.

Dimensions & Thicknesses

Tempcon sandwich panel is available in a single outer profile type in both steel and aluminium in combination of the below listed inner skin types; the insulating core can be prduced in various thicknesses and thermal insulation values.

Thermal Properties

Panel ID Skin Type Name Code Core "T" Thermal Transmission U-Value Thermal Resistance R-Value
TC Outer Inner   (mm) (W/m2.k) m2K/W
Type S Equal Rib (Q)
TSCQ-30 30 0.733 1.346
TSCQ-40 40 0.550 1.818
TSCQ-50 50 0.440 2.273
TSCQ-75 75 0.293 3.409
TSCQ-100 100 0.22 4.545
Fiber Reinforced Liner (O) TCSO-30 30 0.733 1.364
TCSO-40 40 0.550 1.818
TCSO-50 50 0.440 2.273
TCSO-75 75 0.293 3.409
TCSO-100 100 0.22 4.545

The U-Values in the above table is measured at 25 oC and thermal conductivity of K= 0.022 KW/m oK

Temparch Panel

Temparch sandwich panels are produced using rigid Polyisocyanurate (PIR) foam core with external and internal sheets in steel or aluminum of varying thickness, and are suitable for walls for all building applications, interior partition and cold stores.

Dimensions & Thicknesses

Panel ID Outer Skin Inner Skin Sandwich Panel
Skin Name ID Skin Name ID Name-(Thickness)
TA Micro Rib W
Equal Rib Q - TAWQ-60 TAWQ-75 TAWQ-100
Fiber Reinforced Liner O TAWO-40* TAWO-60 TAWO-75 TAWO-100
Equal Rib U
Equal Rib Q - TAUQ-60 TAUQ-75 TAUQ-100
Fiber Reinforced Liner O TAUO-40* TAUO-60 TAUO-75 TAUO-100
V - Groove V
Equal Rib Q - TAVQ-60 TAVQ-75 TAVQ-100
Fiber Reinforced Liner O TAVO-40* TAVO-60 TAVO-75 TAVO-100

Note: * - This thickness is available for TEMPARCH Wall Panel with Fiber Reinforced Liner only.

Thermal Properties

Panel Thickness Thermal Transmission U-Value Thermal Resistance R-Value
(mm) W/m2K m2K/W
40 0.550 1.818
60 0.367 2.273
75 0.293 3.409
100 0.22 4.545

The U-Values in the above table is measured at 25oC and thermal conductivity of K=0.022 KW/m oK